The New ATP Digital Display

User Interface

Get a feel for the detailed, yet simplistic operator functionality.

User Benefits

Simple

  • 8” touch screen
  • See Current, Peak & Angle values all at once
  • Large numbers
  • Visual graphs
  • Large buttons with glove touch sensitivity

Guidance

  • Optional Visual and Audible Alarms
  • Optional Guided Procedures

Support

  • Videos: How-to and troubleshooting videos within Help section
  • Manuals: PDF manuals within Help Section

Durability

  • Longer Battery Life (24 Continuous hours) with efficient charging options
  • MIL-STD 810G certified, IP68, readily replaceable tablet with multi-functional case

User Screens

Torque Home Screen with Alarm On

View is mostly the same as the torque home screen and will show if an alarm is active. The noticeable difference will be the addition of the white section on your graph defining your set target and minimum/maximum range.

Angle Home Screen with Alarm On

View is mostly the same as the angle home screen and will show if an alarm is active. The noticeable difference will be the addition of the green line on your graph defining your set target and the box with orange text showing your target numeric value.

Stored Procedures Selection

In the procedures tab, you can select from programmed procedures for your applications. This will bring you to a home screen with alarms set to walk you through the various steps of your application through completion.

Video Support

Tool operation and instructional videos available on device.

User Benefits


Simple

  • 8” touch screen
  • See Current, Peak & Angle values all at once
  • Large numbers
  • Visual graphs
  • Large buttons with glove touch sensitivity

Guidance

  • Optional Visual and Audible Alarms
  • Optional Guided Procedures

Support

  • Videos: How-to and troubleshooting videos within Help section
  • Manuals: PDF manuals within Help Section

Durability

  • Longer Battery Life (24 Continuous hours) with efficient charging options
  • MIL-STD 810G certified, IP68, readily replaceable tablet with multi-functional case

User Screens

Torque Home Screen with Alarm On

View is mostly the same as the torque home screen and will show if an alarm is active. The noticeable difference will be the addition of the white section on your graph defining your set target and minimum/maximum range.

Angle Home Screen with Alarm On

View is mostly the same as the angle home screen and will show if an alarm is active. The noticeable difference will be the addition of the green line on your graph defining your set target and the box with orange text showing your target numeric value.

Stored Procedures Selection

In the procedures tab, you can select from programmed procedures for your applications. This will bring you to a home screen with alarms set to walk you through the various steps of your application through completion.

Video Support

Tool operation and instructional videos available on device.

Data Management

See engineering controls, settings, research and data capture capabilities.

Data Management Benefits

Data (Automatic)

  • Data storage (internally store last 500 events)
  • Data graphing – quickly see how your installation looks
  • Easy exporting through Micro USB

Procedures (Optional)

  • Consistent Process
  • Easily identify torque events

Back-end control (Optional)

Data Management Screens

Stored Data

In management controls you can review and export stored data (up to 500 events)

Procedure Settings

Within the procedure settings screen you can create new procedures, or import, export, edit, delete and duplicate existing procedures.

Creating a New Procedure

This screen shows the simplicity of creating a procedure. Choose angle or torque mode, fill in values and instructions and complete or add another step.

Management Controls

Control what options are available to the tool operator.

Data Management Benefits

Data (Automatic)

  • Data storage (internally store last 500 events)
  • Data graphing – quickly see how your installation looks
  • Easy exporting through Micro USB

Procedures (Optional)

  • Consistent Process
  • Easily identify torque events

Back-end control (Optional)

Data Management Screens

Stored Data

In management controls you can review and export stored data (up to 500 events)

Procedure Settings

Within the procedure settings screen you can create new procedures, or import, export, edit, delete and duplicate existing procedures.

Creating a New Procedure

This screen shows the simplicity of creating a procedure. Choose angle or torque mode, fill in values and instructions and complete or add another step.

Management Controls

Control what options are available to the tool operator.

Calibration

Walk through a calibration.

Calibration Benefits

Procedure Improvements

  • Achieve better results with ease
  • Our new process guides you though the process

Information Tracking

  • Calibration history, alert when calibration is due
  • Track usage (store last 500 events)
  • Increased error messages to help avoid misuse
  • Stored over-torque events – (Date, Time, Force)

Support

  • How-to videos and owner manual stored within device

Calibration Screens

Calibration Login

Management login to secure calibration mode from unauthorized use.

Calibration As Found Reading

As Found readings. Option to complete if no calibration is needed or adjust to begin calibration.

Calibration Clockwise

5 point clockwise calibration mode.

Calibration Counter Clockwise

5 point counter clockwise calibration mode.

Calibration Complete

Calibration complete verification and set next calibration due. Also choose to lockout device from use if past due.

Calibration Benefits

Procedure Improvements

  • Achieve better results with ease
  • Our new process guides you though the process

Information Tracking

  • Calibration history, alert when calibration is due
  • Track usage (store last 500 events)
  • Increased error messages to help avoid misuse
  • Stored over-torque events – (Date, Time, Force)

Support

  • How-to videos and owner manual stored within device

Calibration Screens

Calibration Login

Management login to secure calibration mode from unauthorized use.

Calibration As Found Reading

As Found readings. Option to complete if no calibration is needed or adjust to begin calibration.

Calibration Clockwise

5 point clockwise calibration mode.

Calibration Counter Clockwise

5 point counter clockwise calibration mode.

Calibration Complete

Calibration complete verification and set next calibration due. Also choose to lockout device from use if past due.

U.S. Patent Nos. 8,434,389 and 8,991,284

 

Canadian Patent No. 2,752,088

 

Japanese Patent No. 5699338